Menu

Archive

Automation Hub Has No Power (Diagnostic LED Off & Never Flashing)

Problem Cause 1 AC Power Adapter is not receiving power. Suggested Solution Check that the power outlet is energized and that the circuit breaker is not tripped. Check that the AC power plug is securely plugged into the electrical outlet. Problem Cause 2 Power link cable is disconnected. Suggested Solution Check that the AC power […]

No Ambient Sensor Readings

Possible Cause 1 Sensor link cable is disconnected. Suggestion Solution Check that the Ambient Sensor link cable is securely connected to the Automation Hub sensor link cable. Check that the sensor link cable is plugged into connection J1 on the Automation Hub circuit board. Possible Cause 2 Defective or incorrectly configured Ambient Sensor. Suggested Solution […]

No Communication to Remote Units

Possible Cause 1 Remote units are outside wireless range. Suggested Solution Ensure Remote units are within 500 meters or 1600 feet of the Automation Hub and have clear line-of-sight. Possible Cause 2 Primary antenna connection is loose. Suggested Solution Ensure the primary (external) antenna connection on the bottom of the Automation Hub is tight and […]

Bin-Sense Plus Unable to Connect to Servers

Possible Cause 1 Outside cellular coverage range. Suggestion Solution Move the Automation Hub to a location with better cellular coverage or clearer line of site to the nearest cell tower. Possible Cause 2 Cellular antenna is disconnected from circuit board. Suggestion Solution Ensure the cellular antenna is securely snapped onto J3 on the modem circuit […]

Reports

The Reports page provides a convenient way to check the status of your site and equipment. It includes information on devices and cables reporting, as well as the ability to check when each device last called in. Login to your Bin-Sense account Go to Reports Site Report Provides an overview of the following: Devices reported […]

Bin-Sense Plus FAQs

When was Bin-Sense Plus released? April 2023. How often does a Bin-Sense Plus site/Automation Hub call in? Every 5 minutes (5 minutes, 20 seconds to be exact). In contrast, a Bin-Sense Live master calls in every 68 minutes. How does Bin-Sense Plus syStem get power? The Automation Hub needs to be plugged in to AC […]

What To Do After Replacing Remote Batteries

After the batteries in your remote units have been replaced, you would need to send scan commands for the remote units to resume call-in. The remote unit goes into a high-power state for 3 days before they stop searching for the master unit. The scan commands that are sent within 3 days of replacing the […]

Bin-Sense Solo User Manual

Click here for Bin-Sense Solo User Manual. For more manuals and guides, please visit our Support page.

Bin-Sense Solo

For Bin-Sense Solo User Manual, please click here. Overview The Solo unit is used to automatically read up to four sensing cables once daily and send grain condition information to the Bin-Sense Mobile app using a cellular connection. Each bin to be monitored requires the installation of one Solo unit. Two different versions of Solo […]

Single Cable Installation